SUNRESIN
Stock Code 300487
Home
Products
Products
Agarose-Based Chromatography Resins
Agarose-Based Chromatography Resins
Affinity Chromatography – Agarose
Affinity Chromatography – Agarose
Metal Chelate (IDA, NTA)
Metal Chelate (IDA, NTA)

Seplife® 6AG IDA/Ni/90

  • Nickel loaded for high specific binding with His-tagged recombinant proteins
  • Ideal for small or large scale purification under native or denaturing conditions
  • Regulatory Support File (RSF) documentation available
  • Seplife® 6AG IDA/Ni/90 is a metal affinity chromatography resin based on highly cross-linked (6%) agarose functionalized with iminodiacetic acid (IDA) and loaded with Ni.
    It has a high affinity for His-tagged proteins and a large particle size of 45-165 micron. The agarose IDA has high CIP stability <1.0m NaOH when not nickel-loaded.
Request a Quote
Products

Properties

Product

Seplife® 6AG IDA/Ni/90

Appearance

Light blue spherical beads

Type

Metal affinity

Matrix

6% cross-linked agarose

Ligand

Ni/Iminodiacetic acid

10% dynamic binding capacity (mg /ml)*

≥45

Particle size range (μm)

45-165

pH stability

3-12 (operational), 2-14 (CIP)

Chemical Stability

Avoid using Chelating agents including citrate derivatives

Flow rate** (cm/h)

Max 750cm/h

Shipped as

20% ethanol slurry

*Testing conditions: Chromatography column 16mm×200mm; column bed height 20cm; temperature 25°C; mobile phase water.

** Testing conditions: Binding buffer: PBS, 15mM imidazole, pH 7.3 elution buffer: PBS, 250mM imidazole, pH 7.3 Sample: His-tag protein Column 8mm*100mm, room temperature, Retention time 2 minutes.

 

Instructions

Column packing

Column loading should be performed in accordance with standard operating procedures. It is important to ensure that each material is at its working temperature, and when possible, the chromatography media may be degassed before column packing.

Equilibration

Equilibrate the column with an appropriate 2-5 column volume buffer. Ensure the conductivity and pH of the effluent are exactly the same as the buffer.

Sample feeding

1. The sample is generally dissolved in the equilibration buffer solution with pH 6-8, and increasing the pH of the loading buffer can increase the loading capacity.

2. The buffer should not contain metal chelating agents such as EDTA and citrate, and it is best to avoid reducing agents such as mercaptoethanol and DTT.

3. Commonly used buffers include 10-100 mmol/L sodium phosphate, 20-200 mmol/L Tris-HCl, etc.

4. Generally, 0.15-0.5mol/L NaCl should be added to the buffer to eliminate any ion exchange interactions.

5. When using the nickel chelate agarose media for the first time, it is recommended to use 50mmol/L PBS (50 mmol/L NaH 2 PO 4 , 0.5 mol/L NaCl, pH 7.4) as the initial buffer.

Elution

Typically, the following methods can be used for protein elution:

1. Lower pH: most proteins will be eluted at pH 6-4 (also at pH 3-4), the buffer can be sodium acetate, and phosphate buffer systems.

2. Competitive elution: linearly increase or one-step increase the concentration of competing substances with affinity to metal ions (such as 0-1.0 mol/L imidazole, 0-50 mmol/L histidine, 0-2 mol/L NH 4 Cl ).

3. Chelating agents: Chelating agents such as EDTA and EGTA can bind to metal ions and release the proteins. However, this method cannot separate different proteins and will remove the metal from the resin.

Note :

1. When using for the first time, if the concentration required for elution is not certain, it is recommended to add 10mmol/L, 20mmol/L, 50mmol/L, 100mmol/L, 200mmol/L, 500mmol/L imidazole to the initial buffer solution, from low to high concentration, to elute and collect the recombinant proteins respectively, and then identify the elution results by SDS-PAGE electrophoresis and other methods. If conditions permit, linear imidazole gradient elution can be performed to determine better elution conditions .

2. Imidazole is alkaline, and the pH needs to be adjusted using HCl after the corresponding buffer solution is prepared.

3. Elution by lowering pH and with chelating agent will cause the metal ions to be removed from the resin. The Ni ions need to be re-chelated before the next use.

For all the above elution methods, 150-500mmol/L NaCl should be added to the buffer to eliminate any ion exchange interaction.

Regeneration

1. After multiple uses or when the chelated metal ions need to be replaced, the metal must be stripped of the chromatographic media and the resin regenerated.

Metal removal method: First rinse the column with 5-10 CV of distilled water, then rinse the column with 5-10 CV of 100mmol/L EDTA, and finally use 2-3 CV of 0.5mol/L NaCl to wash off residual EDTA .

2. Columns that have been used many times generally require cleaning after metal removal.

Cleaning method: reverse wash the column with 0.1-1.0 mol/L NaOH, and keep it at 50 cm/h for 1-2 hours, which should remove the strongly bound impurities.

3. Metal ions need to be re-chelated after washing.

Chelating method: First, use 2-5 CV of distilled water to fully balance the column after previous metal removal, then use 0.1-0.3mol/L metal salt solution (chloride or sulfate soluble metal salts are suitable) to pass through the column for 5-10 CV to chelate the fresh metal ions, and finally use 5-10 CV of distilled water to remove unbound metal ions.

Cleaning-In-Place (CIP)

When it is found that the performance of the chromatographic media decreases or the back pressure increases, then a cleaning process should be applied. Before cleaning, follow the recommended operation steps to remove Ni 2+  ions.

The chromatography media after nickel removal is generally cleaned with a reversed-phase flow rate, and the following methods can be used

1. Removal of proteins adsorbed by ion exchange: use 2 mol/L NaCl solution to backwash 2 to 3 CV.

2. Removal of hydrophobic proteins and lipids: Backwash 4 CV with 70% ethanol or 30% isopropanol then rinse the chromatography with 10 CV of distilled water column.

3. Removal of precipitated proteins, hydrophobic proteins and lipids: first use 1.0 mol/L NaOH to backwash the column (50 cm/h, contact time 1-2 h), contact for more than 12 hours to remove endotoxin. Then rinse the chromatography column with 10 CV of equilibration buffer, and finally rinse the chromatography column with 5 CV of distilled water.

Storage

Sealed and stored at 4~30°C (preservation solution is 20% ethanol) in a ventilated, dry and clean place, do not freeze. 

Ordering information

Product Name

References

Pack Size

Seplife® 6AG IDA/Ni/90

A4013202

25ml

A4013203

100ml

A4013204

500ml

A4013205

1L

A4013206

5L

A4013207

10L

Production date: See label

Expiry date: 5 years, under proper storage conditions

Get in touch
Please Provide Your Inquiry Details, Our Specialists Are Ready to Assist You.
Send Message
Advanced Cookie Settings
Essential Cookies
These cookies enable core functionality such as security, verification of identity and network management. These cookies can’t be disabled.
Enable Marketing Cookies
These cookies are used to track advertising effectiveness to provide a more relevant service and deliver better ads to suit your interests.
Enable Functional Cookies
These cookies collect data to remember choices users make to improve and give a more personalised experience.
Enable Analytics Cookies
These cookies help us to understand how visitors interact with our website, discover errors and provide a better overall analytics.
Save
We use cookies to make the website work, to provide advanced features, social media and traffic analysis, and we use analytics and third-party advertising cookies. If you choose to click "Deny All", you will retain the default setting of not allowing the use of cookies or other tracking tools other than technical tools.
Accept Cookies
Reject All
Setting
Here to Provide Complete Separation and Purification Solutions
Sunresin is an innovation oriented high-tech enterprise, specialized in supplying Ion exchange resins,adsorption & separation resins, equipment solutions and relevant technical services.
Request a Quote
Copyright © Sunresin New Materials Co., Ltd. All Rights Reserved
  • Privacy Policy
  • Terms of Service
  • SiteMap.html
  • SiteMap.xml
  • Marketing Support by Globalsir
    Document
    Get in touch
    Document
    Please provide your inquiry details, our specialists are ready to assist you.
    Get in touch
    I consent to receive updates and marketing content from Sunresin. I understand that I can opt-out of further communication at any time as explained in the Privacy Policy
    I agree to the Privacy Policy
    Send Message