Product |
Seplife® DX DEAE 50/80 |
Appearance |
White spherical beads |
Type |
Weak base anion - Diethylaminoethyl |
Matrix |
Crossed linked dextran |
Ion exchange capacity (mmol/g) |
3.0 -4.0(Cl-) |
Particle size (dry, μm) |
40-120 |
Swelling property (ml/g) |
75.0-95.0 |
pH stability |
2-9 (operational), 2-12 (CIP) |
Chemical Stability |
Stable in all common aqueous buffers; 1M sodium hydroxide; 8M urea; 6M guanidine hydrochloride; 70% ethanol. Avoid exposure to strong oxidizing agents and dextranase. |
Flow rate* (cm/h) |
max. 60 |
Shipped as |
dry |
*Testing conditions: Chromatography column 16mm×200mm; column bed height 5cm; temperature 25°C; mobile phase 0.1M NaCl
Seplife®DX DEAE 50/80 is provided as a dry powder and needs to be wetted and swollen before use. The swelling ratio depends on the buffer solution used and can vary significantly.
Due to the large variation in volume depending on the buffer composition, Seplife®DX DEAE 50/80 may be more suitable for applications in batch mode.
Do not use magnetic stirring during processing, to avoid breaking the particles.
Weigh the required amount of Seplife®DX DEAE 50/80, add 50~100 times distilled water or equilibration buffer solution and let it swell. Swelling typically takes 1~2 days at room temperature, or 2 hours in boiling water.
Column packing should be done according to standard operating procedures. It is important to ensure that each material is at its working temperature, and the chromatography media may need to be degassed before column packing.
Note: If the column is packed at the maximum linear flow rate, the flow rate during the subsequent chromatographic separation should not exceed 75% of the column packing flow rate.
Equilibrate the column with an appropriate 2-5 column volume buffer. Ensure the conductivity and pH of the effluent are the same as the buffer.
Determine the loading amount according to the target product concentration and the loading capacity of the media. Samples with particulates and precipitate should be filtered or centrifuged before the chromatography purification.
After loading the sample, equilibrate the column with loading buffer to wash away unbound molecules until the conductivity and pH of the effluent are the same as for the loading buffer.
Use continuous or gradient elution with increasing salt concentration in the buffer or decreasing pH.
First wash off the impurity proteins on the column with 1~2M NaCl. Then wash off the salt from the column with distilled water.
Seplife®DX DEAE 50/80 dry powder should be stored in a dry, ventilated and clean place at 4~30℃; the hydrated media should be stored in 20% ethanol solution or 0.1M NaOH at 4~8℃ to control microbial growth.
Product Name |
References |
Pack Size |
Seplife® DX DEAE 50/80 |
D2017310 |
25g |
D2017311 |
100g |
|
D2017312 |
500g |
|
D2017313 |
1kg |
|
D2017314 |
5kg |
|
D2017315 |
10kg |
Production date: See label
Expiry Date: 5 years, under proper storage conditions
Manufacturer: Sunresin New Materials Co. Ltd.
Add:No. 135, Jinye Rd, Xi'an Hi-tech Industrial Development Zone, Shaanxi, 710076, China
www.seplite.com www.sunresin.com
E-mail: info.lifescience@sunresin.com